682 HEIDENHAIN Technical Manual MANUALplus 620
Deactivating an
axis during startup
With the MP_deactivatedAtStart parameter you can deactivate an axis or
spindle already during startup and then activate it later for control operation.
An axis that was deactivated through MP_deactivatedAtStart behaves as if
you have deactivated the axis through Module 9226 or 9418 with mode 14. A
change of the parameter does not go into effect until the next startup of the
MANUALplus 620.
MP_deactivatedAtStart
Deactivate axis during startup
Available from NCK software version: 597 110-04.
Format: Selection menu
Selection: TRUE
During startup of the MANUALplus 620 the axis is
deactivated—irrespective of the parameter MP_axisHw. The
same effect is attained with the setting as from calling PLC
module 9226 or 9418 with mode 14.
FALSE
During startup of the MANUALplus 620 the axis is treated as
configured in the parameter axisHw.
Default: No value, parameter optional (= behavior as for FALSE)
Access: LEVEL3
Reaction: RUN
Note
For all axes that are removable, (e.g. exchangeable milling heads),
HEIDENHAIN recommends setting the MP_deactivatedAtStart
parameter to the value TRUE. In this case, the PLC must ensure that the