712 HEIDENHAIN Technical Manual MANUALplus 620
Compensation:
In MP_linearCompValue, enter the axis error [mm/m].
With MP_compType, activate the linear axis error compensation.
MP_linearCompValue
Linear axis error compensation
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: –1.000 to +1.000 [mm/m]
Default: 0
Access: LEVEL3
Reaction: RUN
MP_compType
Selection of linear/nonlinear axis error compensation
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: linear
Linear axis error compensation is active
non-linear
Nonlinear axis error compensation is active
Default: linear
Access: LEVEL3
Reaction: RUN
If nonlinear axis-error compensation is active (MP_compType = non-
linear), linear axis-error compensation is not available.