826 HEIDENHAIN Technical Manual MANUALplus 620
Machine 
parameters for 
path-specific limit 
values
 In CfgLaPath, define the path-specific limit values for feed rate, acceleration 
and jerk.
MP_minPathFeed allows you to define the minimum feed rate in an NC block. 
The parameter is intended for technological purposes, in particular for 
preventing dwell marks in small radii. If the values are too large, feed-rate 
optimization becomes ineffective. This might lead to excessive dynamic load 
on the machine.
MP_minPathFeed
Minimum feed rate on the path
Available from NCK software version: 597 110-01.
Format: Numerical value 
Input: 0.000 000 000 to 600 000 [mm/min]
Default: 60 [mm/min]
Access: LEVEL3
Reaction: RUN
Settings in the configuration editor MP number
Channels
ChannelSettings
[Key name of the machining channel]
CfgLaPath
minPathFeed
minCornerFeed
maxG1Feed
maxPathJerk
maxPathJerkHi
pathTolerance
pathToleranceHi
maxPathYank
201501
201502
201503
201504
201505
201506
201507
201508
MP_minPathFeed is always limited to the programmed feed rate; this 
means that look-ahead violates the defined minimum feed-rate value only 
if a lower value is programmed in the NC block or is set by the override 