January 2012 6.16 The Control Loop 865
MP_compActDampFact
Damping factor for active damping
Available from NCK software version: 597 110-02.
Format: Numerical value
Input: 0 to 30.000
0: No damping
1.5: Typical damping factor
Default: No value, parameter optional (= 0)
Access: LEVEL3
Reaction: RUN
MP_compActDampTime
Damping time constant for active damping
Available from NCK software version: 597 110-02.
Format: Numerical value
Input: 0 to 0.9999 [s]
0: No damping
0.005 to 0.02: Typical damping time constant
Default: No value, parameter optional (= 0)
Access: LEVEL3
Reaction: RUN