880 HEIDENHAIN Technical Manual MANUALplus 620
MP_driveOffGroup
Circuit of X150/X151
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: None
Axis not assigned (disabling only through I32)
Group1
Axis is assigned to X150 pin 1
Group2
Axis is assigned to X150 pin 2
Group3
Axis is assigned to X150 pin 3
Group4
Axis is assigned to X150 pin 4
Group5
Axis is assigned to X151 pin 1
Group6
Axis is assigned to X151 pin 2
Group7
Axis is assigned to X151 pin 3
Group8
Axis is assigned to X151 pin 4
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
The MANUALplus 620 monitors the time between the switch-on of the drive
controller (by means of PP_AxDriveOnRequest) and the RDY signal (via the
PWM cable). If the READY signal is missing after the waiting time has passed,
the error message 8B40 NO DRIVE ENABLE <axis> appears.
Enter in MP_AmpReadyWaitTime the permissible waiting time.
MP_ampReadyWaitTime
Waiting time between switch-on of the power module and the
RDY signal
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.001 000 000 to 4999 [s]
0: Waiting time of 2 [s]
Default: 0 [s]
Access: LEVEL3
Reaction: RESET
If you disconnect the voltage
-ES.B, all drive controllers are switched off.
on the PLC inputs for axis group enabling, the drive controllers of the
corresponding axis group(s) are switched off.
If drive enabling is missing, the error message 8B40 No drive release
<axis> appears.