954 HEIDENHAIN Technical Manual MANUALplus 620
MP_movementThreshold
Threshold above which the movement monitoring functions
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.000 000 000 to 36 000 000 [mm/min] or [°/min]
0: Monitoring switched off
Default: 199.98 [mm/min] or [°/min]
Access: LEVEL3
Reaction: RUN
MP_thresholdDistance
Tolerance at and above which the following error is included
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0.000 000 000 to 36 000 000 [mm] or [°]
Default: 5 [mm] or [°]
Access: LEVEL3
Reaction: RUN