980 HEIDENHAIN Technical Manual MANUALplus 620
Module 9067 Status of software settings
Module 9067 enables you to request status information about software
settings. Module 9067 can currently be used to interrogate the software
options set in the SIK.
Call:
PS B/W/D/K <>Mode>
0: Interrogate whether SW option is set in the SIK
PS B/W/D/K <>Number>
If mode is 0: Number of SIK option
CM 9067
PL B/W/D <>Status>
Status of SIK option (if mode is 0)
0: Not set
1: Set
Error recognition:
Example:
Query if option 10 is set in the SIK:
PS K0
PS K10
CM 9067
PL DL_statusinfo_9067
M_display_module_error(KG_error_module_9067)
Marker Value Meaning
M4203 or
NN_GenApiModule
Error
0 Function performed successfully
1 Error code in W1022 or
NN_GenApiModuleErrorCode
W1022 or
NN_GenApiModule
ErrorCode
1 Invalid value for number
2 Invalid value for mode