January 2012 6.17 Monitoring Functions 997
MP_motEncCheckOff
Monitoring functions
Available from NCK software version: 597 110-01.
Format: Numerical value 
Input: Bit 4: – Monitoring for excessive motor temperature
0: Monitoring active
1: Monitoring inactive
Bit 5: – Monitoring for too low a motor temperature
0: Monitoring active
1: Monitoring inactive
Bit 7 – Monitoring the input frequency of the speed encoder
0: Monitoring active
1: Monitoring inactive
Bit 8 – Adjust mechanical offset by gradually increasing the k
V
 
factor
0: Function active
1: Function inactive
Default: 0
Access: LEVEL3
Reaction: RESET