Figure 61: Installing the Mounting Hardware for a Two-Post Rack
Open-frame
rack
Large
mounting shelf
Small
mounting shelf
g050125
For a two-postrack, Table 61 on page 232 specifies the holes in which you insert mounting
screws (an X indicates a mounting hole location), and cage nuts if needed. The hole
distances are relative to one of the standard “U” divisions on the rack. For reference, the
bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
Table 61: Two-Post Rack Mounting Hole Locations
Small
ShelfLarge ShelfDistance Above “U” DivisionHole
X9.86 U17.26 in. (43.8 cm)30
X8.86 U15.51 in. (39.4 cm)27
X7.86 U13.76 in. (34.9 cm)24
X6.86 U12.01 in. (30.5 cm)21
X5.86 U10.26 in. (26.0 cm)18
X4.86 U8.51 in. (21.6 cm)15
Copyright © 2012, Juniper Networks, Inc.232
QFX3000 Hardware Documentation

Table of Contents

Other manuals for Juniper QFX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX Series and is the answer not in the manual?

Juniper QFX Series Specifications

General IconGeneral
CategorySwitch
SeriesQFX
Form Factor1U, 2U, and modular chassis options
Power SupplyRedundant, hot-swappable power supplies
Coolinghot-swappable fans
Virtual ChassisSupported on certain models
Typical UseData center, cloud
Operating SystemJunos OS
ManagementCLI
Key FeaturesHigh performance, low latency, automation
LatencySub-microsecond latency
Port DensityVaries by model (e.g., QFX5100: up to 48x10GbE + 6x40GbE)

Related product manuals