Table 88: QFX3500 Chassis Alarm Messages
Recommended ActionCLI MessageAlarm TypeComponent
The fan is missing. Install a fan.Fan/Blower AbsentMajor (red)Fans
Replace the fan and report the failure to
customer support.
Fan Failure
Check the system log for one of the
following messages and report the error
message to customer support:
•
CM ENV Monitor: Get fan speed failed.
•
Fan-number is NOT spinning @ correct
speed, where fan-number may be 1, 2,
or 3.
Fan I2C Failure
Remove and check the fan for
obstructions, and then reinsert the fan. If
the problem persists, replace the fan.
Fan fan-number Not Spinning