Chassis Physical Specifications for a QFX3100 Director Device on page 25
Chassis Physical Specifications for a QFX3008-I Interconnect Device on page 41
Chassis Physical Specifications for a QFX3500 Chassis on page 64
Chassis Physical Specifications for EX4200 Switches
Cabling requirements for the control plane and management network—The control
plane and management network are interconnected using standard 1000BASE-T
Ethernetover copper wiring. Each network segment can be a maximum lengthof 100 m
(328 ft). See “Cable Specifications for Control Plane Connections for the QFX Series”
on page 129.
Cabling requirements for the data plane—The data plane is interconnected using
standard 40GBASE-SR40-Gigabit Ethernet QSFP+ optical transceivers over fiber-optic
wiring. If you use OM3 optical fiber, each network segment can be a maximum of 100 m
(328 ft). If you use OM4 optical fiber, each network segment can be a maximum of
150 m (492 ft). However, keep in mind that each network segment in the control plane
and management network is limited to a maximum length of 100 m (328 ft). See
“Interface Specifications for Data Plane Connections for the QFabric System” on
page 127.
Power supplyYou must plan the installation site to meet the power requirements of
all the devices in the QFX3000 QFabric system. For information on powerrequirements
and configuration options for each device, see the following topics:
AC Power Specifications for a QFX3100 Director Device on page 135
AC Power Specifications for a QFX3008-I Interconnect Device with Single-Phase
Wiring Trays on page 137
AC Power Specifications for a QFX3008-I Interconnect Device with Three-Phase
Delta Wiring Trays on page 138
AC Power Specifications for a QFX3008-I Interconnect Device with Three-Phase
Wye Wiring Trays on page 138
AC Power Specifications for a QFX3500 Device on page 147
Power Specifications for EX4200 Switches
For more information about the site preparation requirements for each device, see the
following topics:
Site Preparation Checklist for a QFX3100 Director Device on page 83
Site Preparation Checklist for a QFX3008-I Interconnect Device on page 84
Site Preparation Checklist for a QFX3500 Device on page 86
Site Preparation Checklist for EX4200 Switches
Related
Documentation
QFX3000-G QFabric System Installation Overview on page 209
Copyright © 2012, Juniper Networks, Inc.82
QFX3000 Hardware Documentation

Table of Contents

Other manuals for Juniper QFX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX Series and is the answer not in the manual?

Juniper QFX Series Specifications

General IconGeneral
CategorySwitch
SeriesQFX
Form Factor1U, 2U, and modular chassis options
Power SupplyRedundant, hot-swappable power supplies
Coolinghot-swappable fans
Virtual ChassisSupported on certain models
Typical UseData center, cloud
Operating SystemJunos OS
ManagementCLI
Key FeaturesHigh performance, low latency, automation
LatencySub-microsecond latency
Port DensityVaries by model (e.g., QFX5100: up to 48x10GbE + 6x40GbE)