Table 88: QFX3500 Chassis Alarm Messages (continued)
Recommended ActionCLI MessageAlarm TypeComponent
Check the system log for the following
message and report it to customer
support:
Temp sensor sensor-number failed, where
sensor-number mayrangefrom 1 through
10.
sensor-location Temp Sensor FailMajor (red)Temperature
sensors
Check environmental conditions and
alarms on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) are not
affecting the temperature sensor. If the
condition persists, the device may shut
down.
sensor-location Temp Sensor Too Hot
For information only. Check
environmental conditions and alarms on
other devices.Ensure that environmental
factors (such as hot air blowing around
the equipment) are not affecting the
temperature sensor.
sensor-location Temp Sensor Too WarmMinor (yellow)
Related
Documentation
Front Panel of a QFX3500 Device on page 65•
• Configuring the Junos OS to Determine Conditions That Trigger Alarms on Different
Interface Types
• alarm
Interface Alarm Messages
Interface alarms are alarms that you configure to alert you when an interface is down.
By default, interface alarms are not configured.
To configure an interface link-down condition to trigger a red or yellow alarm, or to
configure the link-down condition to be ignored, use the alarm statement at the [edit
chassis] hierarchy level. You can specify the ethernet, fibre-channel, or
management-ethernet interface type.
Related
Documentation
• Understanding Alarms on page 437
• alarm