Ensure that you havetaken the necessary precautions to prevent electrostatic discharge
(ESD) damage. See “Prevention of Electrostatic Discharge Damage” on page 192.
Ensure that you do not need to forward traffic through the device.
Determine whether the Control Board is the master or backup using one of these
methods:
Check the MASTER LED on the Control Board faceplate. If the MASTER LED is lit
steady green, the Control Board is the master.
Issue the show chassis routing-engine CLI command.
Ensure that you have the following parts and tools available to power off the device:
An ESD grounding strap
An external management device such as a PC
An RJ-45 to DB-9 rollover cable to connect the external management device to the
console (CON) port
To take the Control Board offline in a QFX3008-I Interconnect device, perform the tasks
appropriate for your device:
1.
Taking a Master Control Board Offline on page 346
2.
Taking a Backup Control Board Offline on page 347
Taking a Master Control Board Offline
To take a master Control Board offline in a QFX3008-I Interconnect device:
1. Connect a management device to the console (CONSOLE) port on the master Control
Board in the QFX3008-I Interconnect device. For instructions about connecting a
management device to the console (CONSOLE) port, see “Connecting a QFX Series
Device to a Management Console” on page 285.
2. Make the master Control Board the backup Control Board by using the request chassis
routing-engine master switch CLI command.
The current backup Control Board becomes the master Control Board after this
command is issued.
CAUTION: Until the backup Control Board assumes mastership, no data
traffic is forwarded over the QFX3008-I Interconnect device. Data traffic
over other QFX3008-I Interconnect devices in your QFX3000 QFabric
system is not disrupted.
3. Use the show chassis routing-engine command to confirm thatmastership haschanged.
4. Connect the management device to the console (CONSOLE) port on the new master
Control Board in the QFX3008-I Interconnect device.
Copyright © 2012, Juniper Networks, Inc.346
QFX3000 Hardware Documentation

Table of Contents

Other manuals for Juniper QFX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX Series and is the answer not in the manual?

Juniper QFX Series Specifications

General IconGeneral
CategorySwitch
SeriesQFX
Form Factor1U, 2U, and modular chassis options
Power SupplyRedundant, hot-swappable power supplies
Coolinghot-swappable fans
Virtual ChassisSupported on certain models
Typical UseData center, cloud
Operating SystemJunos OS
ManagementCLI
Key FeaturesHigh performance, low latency, automation
LatencySub-microsecond latency
Port DensityVaries by model (e.g., QFX5100: up to 48x10GbE + 6x40GbE)

Related product manuals