Related
Documentation
Installing a Bottom Air Filter in a QFX3008-I Interconnect Device on page 340•
• Cooling System and Airflow in a QFX3008-I Interconnect Device on page 44
• Field-Replaceable Units in a QFX3008-I Interconnect Device on page 38
Installing a Bottom Air Filter in a QFX3008-I Interconnect Device
A QFX3008-I Interconnect device bottom air filter is located beneath the bottom fan
tray and front panel display. Two captive screws on either side of the air filter door secure
the air filter in the chassis.
CAUTION: Do not run the devicefor more than 2 minutes without the air filter
in place.
CAUTION: Always keep the air filter in place while the device is operating,
except during replacement. Because the fans are very powerful, they could
pull small bits of wire or other materials into the devicethroughthe unfiltered
air intake. This could damage device components.
Before you install a bottom air filter, ensure that you understand how to prevent ESD
damage. See “Prevention of Electrostatic Discharge Damage” on page 192.
Ensure that you have the following parts and tools available to install a bottom air filter
in a QFX3008-I Interconnect device:
•
Electrostatic discharge (ESD) grounding strap
To install the air filter (see Figure 107 on page 341):
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
the strap to one of the ESD points on the chassis.
2. If the air filter door is closed, unscrew the captive screws on each side of the air filter
door, and pull the door open.
3. Slide the air filter into the chassis. The air filter has a label indicating which side should
be facing up.
4. Close the air filter door, and tighten the captive screws on each side of the air filter
door.