Adjusting the Images That Were Taken
100
FQ2-S/CH User’s Manual
• Extracting Only a Specified Range of Brightness
You set the upper and lower limits of the brightness range to extract with the Background Suppression item.
[Image] [Image adjustment] [Background suppression] [Modify]
1 Press [ ] [Suppression level] on the right
of the display.
2 Press [ ] [RGB setting] on the right of the
display.
3 Select the method to use to specify the bright-
ness range. (This setting applies to Sensors
with Color Cameras only.)
Common RGB Settings
Set the upper and lower limit values of the bright-
ness range. The same limits will be used for all
RGB colors.
Individual RGB Settings
Set the upper and lower limit values of the bright-
ness range for each RGB color. Press [R], [G], and
[B] and set the upper and lower limits for each of
them.
4 Set the upper and lower limit values of the
brightness range. (for Sensors with Mono-
chrome Cameras (or after a Color Gray Filter))
5 Press [Back].
6 Press [OK].
7 Press [Back].
Lower limit
Upper limit

Table of Contents