Adjusting the Images That Were Taken
124
FQ2-S/CH User’s Manual
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Expression
text string
Data name Description Data range
JG Judgement This is the judgment result.
-2: No judgement
(not measured)
0: Judgement is OK
-1: Judgement is NG
-15: Out of range error
DT Scroll q This is the amount of position
compensation.
-180 to 180
X0 Edge 0 position X This is the X coordinate of the
measured edge 0 position.
-99,999.9999 to 99,999.9999
Y0 Edge 0 position Y This is the Y coordinate of the
measured edge 0 position.
-99,999.9999 to 99,999.9999
X1 Edge 1 position X This is the X coordinate of the
measured edge 1 position.
-99,999.9999 to 99,999.9999
Y1 Edge 1 position Y This is the Y coordinate of the
measured edge 1 position.
-99,999.9999 to 99,999.9999
TH Angle (edge angle) This is the measured angle. -180 to 180
SX0
Edg0 ref. pos.
(edge 0 reference position X)
This is the X coordinate of the
edge 0 position when it was regis-
tered.
-99,999.9999 to 99,999.9999
SY0
Edg0 ref. pos. Y
(edge 0 reference position Y)
This is the Y coordinate of the
edge 0 position when it was reg-
istered.
-99,999.9999 to 99,999.9999
SX1
Edg1 ref. pos. X
(edge 1 reference position X)
This is the X coordinate of the
edge 1 position when it was regis-
tered.
-99,999.9999 to 99,999.9999
SY1
Edg1 ref. pos. Y
(edge 1 reference position Y)
This is the Y coordinate of the
edge 1 position when it was regis-
tered.
-99,999.9999 to 99,999.9999
STH Reference angle This is the angle when the edge
was registered.
-180 to 180