Adjusting the Images That Were Taken
FQ2-S/CH User’s Manual
125
3
Taking Images
• Measurement Data That Can Be Logged
The values below can be logged as measurement data.
Position Compensation
The position is corrected based on the entered numeric values.
This is used to correct the position by rotating the captured image around the center of the screen or entering
numeric values.
[Image] [Image adjustment]
Parameter Setting Description
Judgement
-2: No judgement (not measured)
0: Judgement is OK
-1: Judgement is NG
-15: Out of range error
This is the judgement result.
Scroll q -180 to 180 This is the amount of position compensation.
Angle (edge angle) -180 to 180 This is the measured angle.
Edge 0 position X -99,999.9999 to 99,999.9999 This is the X coordinate of the measured edge 0position.
Edge 0 position Y -99,999.9999 to 99,999.9999 This is the Y coordinate of the measured edge 0position.
Edge 1 position X -99,999.9999 to 99,999.9999 This is the X coordinate of the measured edge 1position.
Edge 1 position Y -99,999.9999 to 99,999.9999 This is the Y coordinate of the measured edge 1position.
1 Press a free number, and press [Add pos. comp.].
2 Press [Value] [Position comp.]