Reading Barcodes
184
FQ2-S/CH User’s Manual
9 Press [Back].
Setup Item Setting Value Description
Verif. master data
OFF(Default) Sets whether to verify the character string that was read from the
barcode against a character string that is registered in the master
data.
To verify the read character string against the master data, select
the character string to use for verification.
All master data
Master data 0 to 31
Partial verif. on/off
No (Default) The number of digits in the read results to be verified with the mas-
ter data can be limited. When [Partial verification] is set to Yes, set
the first and last compared digit positions. Up to 32 characters can
be set as the number of digits.
Example: First compared digit 2, last compared digit 6
The text string used for verification becomes "MRON2".
Manually register “MRON2”, the comparison
character string, in master data registration.
Yes
Partial Verif. setup
1 to 1024
Default
First digit: 1, last digit:
1024)
Master data regist. ---
Registers a character string in the master data.
When using Partial verification, after automatically registering the
master data, you should then adjust the data manually.
External teach No.
Off (Default) Sets the character string in which to automatically register the read
result for teaching from an external device.
Master data 0 to 31
OMR ON 2 0 0 8