Loading...
Inspecting with the Edge Position Inspection Item
278
FQ2-S/CH User’s Manual
Screen Display When the Edge Level and Noise Level Are Changing
A bar showing the threshold level moves up and down on the graphic as the edge level/noise level value changes.
A cross-key cursor will also appear at the detected edge position.
Undesired Edge Position Is Automatically Detected When Teaching (Sensors with Color Cameras Only)
Manually set the color of the edge that you want to detect.
[Inspect] [Inspection] [Edge Position] [Modify] [Settings] Tab Page [Teach]
1 Press [ ] – [Color ON/OFF] on the right side of the display.
2 Press [ON].
3 Press [ ] [Set color.] on the right of the display.
4 Press [ ] [Detection mode] on the right of the
display and select one of the following detec-
tion modes.
5 Draw a rectangle around the color that you want
to use to extract an edge.
The specified color will be extracted.
(Only a rectangle can be used to specify the region.)
6 Press [OK] to enter the edge color.
7 Press [TEACH] again.
8 Press [Back].
Edge level (Blue)
Noise level (Yellow)
Screen display when the edge level are changing.