Calculations and Judgments Using Inspection Item Data
FQ2-S/CH User’s Manual
335
4
Setting Up Inspections
2D-code (DPM)
(FQ2-S4 only)
Judgement JG
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−16: Measurement timeout error
−2
Index No. IN
−2: Verification OFF or reading error,
−1: Verification is NG,
0 to 31: Master data No.
−2
Num. of char. N 0 to 1024 0
Cell Recog. Rate E 0 to 100 0
Contrast C 0 to 100 0
Focus F 0 to 100 0
Cell size P Depends on the size of the code being
read
0
Overall quality GDA0 0 to 4 0
Decode GDA1 0 to 4 0
Cell contrast GDA2 0 to 4 0
Cell modulation GDA3 0 to 4 0
Fixed pattern damage GDA4 0 to 4 0
Axial nonuniformity GDA5 0 to 4 0
Grid nonuniformity GDA6 0 to 4 0
Unused err. Corr. GDA7 0 to 4 0
Search
(FQ2-S1/S2/S3/S4 only)
Judgement JG
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
−2
Correlation CR[0] to CR[31] 0 to 100 0
Position X X[0] to X[31] −99999.9999 to 99999.9999 0
Position Y Y[0] to Y[31] −99999.9999 to 99999.9999 0
Angle TH[0] to TH[31] −180 to 180 0
Reference X SX −99999.9999 to 99999.9999 0
Reference Y SY −99999.9999 to 99999.9999 0
Reference angle ST −180 to 180 0
Detection X RX −99999.9999 to 99999.9999 0
Detection Y RY −99999.9999 to 99999.9999 0
Count C 0 to 32 0
Inspection item Data name Expression
text string