Calculations and Judgments Using Inspection Item Data
334
FQ2-S/CH User’s Manual
OCR
(FQ2-S4/CH only)
Individual similarity SMC 0 to 100 0
Individual stability SBC 0 to 100 0
Bar code
(FQ2-S4 only)
Judgement
JG
2: No judgement (not measured)
0: Judgement is OK
1: Judgement is NG
16: Measurement timeout error
2
Index No. IN
2:No verification pastern
or reading error
1: Verification is NG,
0 to 31: Master data No.
2
Num. of char. N 0 to 1024 0
2D-code
(FQ2-S4 only)
Judgement JG
2: No judgement (not measured),
0: Judgement is OK
1: Judgement is NG
16: Measurement timeout error
2
Index No. IN
2: Verification OFF or reading error
1: Verification is NG
0 to 31: Master data No.
2
Num. of char. N 0 to 1024 0
Overall quality GD0 0 to 4 0
Decode GD1 0 to 4 0
Cell contrast GD2 0 to 4 0
Cell modulation GD3 0 to 4 0
Fixed pattern damage GD4 0 to 4 0
Axial nonuniformity GD5 0 to 4 0
Grid nonuniformity GD6 0 to 4 0
Unused err. Corr. GD7 0 to 4 0
Print scale GD8 0 to 4 0
Print scale X GD9 0 to 4 0
Print scale Y GD10 0 to 4 0
*1:Depends on the model. Refer to Compensating for Position Offset (Position Compensation Items): p. 102.
Inspection item Data name Expression