Calculations and Judgments Using Inspection Item Data
FQ2-S/CH User’s Manual
333
4
Setting Up Inspections
Edge rot. pos. Comp.
(FQ2-S1/S2/S3/S4/CH)
Judgement JG
2: No judgement (not measured)
0: Judgement is OK
1: Judgement is NG
2
Scroll θ DT 180 to 180 0
Edge0 position X X0 99999.9999 to 99999.9999 0
Edge0 position Y Y0 99999.9999 to 99999.9999 0
Edge1 position X X1 99999.9999 to 99999.9999 0
Edge1 position Y Y1 99999.9999 to 99999.9999 0
Angle TH 180 to 180 0
Edge0 ref. position X
(edge 0 reference. position X)
SX0 99999.9999 to 99999.9999 0
Edge0 ref. position Y
(edge 0 reference. position Y)
SY0 99999.9999 to 99999.9999 0
Edge1 ref. position X
(edge 1 reference. position X)
SX1 99999.9999 to 99999.9999 0
Edge1 ref. position Y
(edge 1 reference. position Y)
SY1 99999.9999 to 99999.9999 0
Reference angle STH 180 to 180 0
Numerical Position
Compensation
(FQ2-S1/S2/S3/S4/CH)
Judgement JG
2: No judgment (not measured)
0: Judgement is OK
1: Judgement is NG
15: Out of range error
2
Position correction X DX 99999.9999 to 99999.9999 0
Position correction Y DY 99999.9999 to 99999.9999 0
Position correction θ DT 180 to 180 0
Measurement coordinate X X 99999.9999 to 99999.9999 *1
Measurement coordinate Y Y 99999.9999 to 99999.9999 *1
Measurement angle TH 180 to 180 0
Reference coordinate X SX 99999.9999 to 99999.9999 *1
Reference coordinate Y SY 99999.9999 to 99999.9999 *1
Reference angle ST 180 to 180 90
OCR
(FQ2-S4/CH only)
Judgement JG
2: No judgment (not measured)
0: Judgement is OK
1: Judgement is NG
16: Measurement timeout error
17: Format not entered error
2
Index IN
2: No verification pastern, or reading
error
1: Verification is NG
0 to 31: Master data No.
2
Number of read characters N 0 to 128 0
Similarity SIM 0 to 100 0
Stability STB 0 to 100 0
Number of read characters
(line 1) N1
N1 32 characters max. 0
Number of read characters
(line 2) N2
N2 32 characters max. 0
Number of read characters
(line 3) N3
N3 32 characters max. 0
Number of read characters
(line 4) N4
N4 32 characters max. 0
Inspection item Data name Expression