Configuring the Run Mode Display
FQ2-S/CH User’s Manual
357
6
Operation
Clearing the Measurement Result
You can clear the measurement results of all the configured inspection items by using the following operations.
(Run Mode) [Clear results]
Selecting the Displayed Image
You can select the displayed image when you use the Area or Labeling Inspection items,
(Run Mode) [Display Setting]
The selectable image will be changed depending on the Sensor type.
Color type Monochrome type
You can select from Measurement image,
All color image and Binary image.
(Default : Measurement image)
You can select from Measurement image and Binary image.
(Default : Measurement image)