Logging Measurement Data and Image Data
400
FQ2-S/CH User’s Manual
Ensuring That All Measurement Results Are Logged in External Memory
To ensure that all measurement results are actually saved, change the settings so that the BUSY signal
remains ON until logging has been completed. During operation, do not input the next trigger until the BUSY
signal turns OFF.
[In/Out] − [I/O setting] − [I/O terminals] − [Output] Tab Page − [BUSY output]
Change the BUSY output parameter to [Data logging].
• File logging cannot be used when performing continuous measurements.
• If you use the PC Tool, the logging time may vary by up to 100 ms depending on the application conditions of your
computer.
• If logging data to an SD card, the write time varies depending on the amount of the available space on the SD
card.
Reference value: For SDHC class 4, the time required to write image data is approx. 200 to 800 ms.
Data
Logging
Display
Measurements
Image input
Sensor
Touch Finder
Trigger signal
Image
Logging
BUSY
ON
OFF
Note

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ2-S/CH Series and is the answer not in the manual?

Omron FQ2-S/CH Series Specifications

General IconGeneral
BrandOmron
ModelFQ2-S/CH Series
CategoryDigital Camera
LanguageEnglish

Related product manuals