Setting the Retry Function
426
FQ2-S/CH User’s Manual
Reading order of the Sort order
The scanning procedure when the sort order is set to auto is shown below.
1st : The last Scene which was scanned successfully.
2nd and following: Scene order by most successful scans
In the Default state, the order is the order of the scene numbers.
If the power is interrupted or the sensor is restarted, the success counts are initialized when adjust mode is entered.
For the timing chart, refer to the following manual:
FQ2-S/CH Series User's Manual for Communications Settings (Cat. No. Z338)
Scan criteria for last successful Scan.
Scene 1
Success count: 25
Scene 1
Success count: 25
Scene 2
Success count: 1
Scene 2
Success count: 1
Scene 3
Success count: 50
Scene 3
Success count: 50
Scene 4
Success count: 15
Scene 4
Success count: 15
Scene 5
Success count: 9
Scene 5
Success count: 9