External Reference Parameters
FQ2-S/CH User’s Manual
481
Appendices
9
134 Detec-
tion
point
coordi-
nate
Detection point X Set / Get 0 to 9999 0 --- ---
135 Detection point Y Set / Get 0 to 9999 0 --- ---
136 Mea-
sure-
ment
condition
Sort condition Set / Get 0: Ascending order of correlation
    value,
1: Descending order of correlation
    value,
2: Ascending order of position X,
3: Descending order of position X,
4: Ascending order of position Y,
5: Descending order of position Y
1 --- ---
138 Judge-
ment
condi-
tions
Judgement upper limit
for correlation
Set / Get 0 to 100 100 --- Judgement
condition
139 Judgement lower limit
for correlation
Set / Get 0 to 100 0 --- Judgement
condition
140 Judgement upper limit
for detection count
Set / Get 0 to 32 32 --- Judgement
condition
141 Setting/Acquisition Set / Get 0 to 32 0 --- Judgement
condition
142 Judgement upper limit
for search coordinate 
X
Set / Get −99,999.9999 to 99,999.9999
99,999.9999
--- Judgement
condition
143 Judgement lower limit
for search coordinate 
X
Set / Get −99,999.9999 to 99,999.9999
−99,999.999
9
--- Judgement
condition
144 Judgement upper limit
for search coordinate 
Y
Set / Get −99,999.9999 to 99,999.9999
99,999.9999
--- Judgement
condition
145 Judgement lower limit
for search coordinate 
Y
Set / Get −99,999.9999 to 99,999.9999
−99,999.999
9
--- Judgement
condition
146 Judgement upper limit
for search angle
Set / Get -180 to 180 180 --- Judgement
condition
147 Judgement lower limit
for search angle
Set / Get -180 to 180 -180 --- Judgement
condition
152 Mea-
sure-
ment
condi-
tions
Extraction condition, X
upper limit
Set / Get −99,999.9999 to 99,999.9999
99,999.9999
--- Judgement
condition
153 Extraction condition, X
lower limit
Set / Get −99,999.9999 to 99,999.9999
−99,999.999
9
--- Judgement
condition
154 Extraction condition, Y
upper limit
Set / Get −99,999.9999 to 99,999.9999
99,999.9999
--- Judgement
condition
155 Extraction condition, Y
lower limit
Set / Get −99,999.9999 to 99,999.9999
−99,999.999
9
--- Judgement
condition
161 Detection count Set / Get 1 to 32 32 --- ---
170 Number of data log
records upper limit
Set / Get 0: Fast
1: Stable
0 --- ---
300 Number of data log
records upper limit
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
310 Data logging switch for
entire unit
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
311 Data logging switch for
judgement
Set / Get 0: Data logging OFF
1: Data logging ON
1 --- ---
External 
refer-
ence 
number
Category Data name
Set / Get
Data range Default Expression 
text string
Logged data/
Judgement 
parameter