EasyManua.ls Logo

Omron FQ2-S/CH Series

Omron FQ2-S/CH Series
590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Adjusting the Images That Were Taken
FQ2-S/CH User’s Manual
97
3
Taking Images
•RGB
•HSV
5 Press [OK].
6 Press [Back].
Parameter Setting Description
Filter settings
Red filter (Default)
Green filter
Blue filter
Cyan filter
Magenta filter
•Yellow filter
Brgt.F (brightness filter) (R+G+B)
Brgt.F (brightness filter) (R+2G+B)
Custom filter
These filters achieve the same effect as when
using the selected optical filter.
R Range: 0.0001 to 9.9999
Default: 0.3000 These are the RGB gain settings for a custom
filter.
Increase the gain to increase the density of that
color component.
You can set the gains only if [Custom filter] is
selected in the filter settings.
G Range: 0.0001 to 9.9999
Default: 0.5900
B Range: 0.0001 to 9.9999
Default: 0.1100
Parameter Setting Description
Std. Hue
(standard hue)
Range: 0 to 359
Default: 0
Sets the standard hue for the HSV filter.
The density will decrease as the difference between
the hue and the standard hue increases.
Hue range Range: 10 to 180
Default: 90
Sets the hue range for the HSV filter.
The hue range centered on the standard hue is
divided into 255 levels to find the difference in the
hue. Hues that are outside the hue range will have a
density of 0.
Chroma
(saturation)
Range: 0 to 255 (Default) Set the upper and lower limit values for the chroma
(saturation).

Table of Contents