© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Brake Test
AMT, RBK,
UBK, EFX
1 Touch
, then Touch
.
2 Use the machine control paddle to change
the resistance up and down. The
resistance changes will be displayed in
power bits.
3 Touch STOP to end the test. Touch 
Battery Test
AMT, RBK,
UBK, EFX
1 Touch
, and then Touch
START.
2 The console will display the voltage of
the battery.
3 Touch STOP to end the test. Touch 
SPM
AMT, EFX
1 Touch
, and then
.
2 The console will display Pulse. The
pulse is showing a count of zero
crossings from the generator. SPM shows
a software averaged version of pulse.
An averaged pulse per minute will
display as Minimum and a Maximum pulse.
3 Touch STOP to end the test. Touch 
BACK to exit to Systems Tests.
RPM Test
RBK, EFX
1 Touch
, and then
.
2 The console will display Pulse. The
pulse is showing a count of zero
crossings from the generator. RPM shows
a software averaged version of pulse.
3 Touch STOP to end the test. Touch BACK
CrossRamp
EFX Only
1 Touch
, and then Touch
START.
2 Use the machine control paddle to change
the CrossRamp. The console will display
the analog to digital (A/D) and Glitches
incline position number. Available
battery voltage to the lift system will
be displayed.
3 Touch STOP to end the test. Touch 