RL78/F13, F14 CHAPTER 15 SERIAL ARRAY UNIT
R01UH0368EJ0210 Rev.2.10 838
Dec 10, 2015
Figure 15-27. Procedure for Stopping Master Transmission
Starting setting to stop
Stop setting is completed
Write 1 to the STmn bit of the target channel.
(SEmn = 0 : to operation stop status)
The master transmission is stopped.
Go to the next processing.
Set the SOEmn bit to 0 and stop the output of
the target channel.
Writing the STm register
Changing setting of the SOEm register
TSFmn = 0?
If there is any data being transferred, wait for
their completion.
(If there is an urgent must stop, do not wait)
Yes
No
The levels of the serial clock (CKOmn) and
serial data (SOmn) on the target channel can
be changed if necessitated by an emergency.
To use the STOP mode, reset the serial array
unit by stopping the clock supply to it.
Changing setting of the SOm register
Setting the PER0 register
(Essential)
(Selective)
(Essential)
(Selective)
(Selective)
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0, 1), mn = 00, 01, 10, 11

Table of Contents

Other manuals for Renesas RL78 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas RL78 Series and is the answer not in the manual?

Renesas RL78 Series Specifications

General IconGeneral
CoreRL78
CPU Clock SpeedUp to 32 MHz
Flash MemoryUp to 512 KB
RAMUp to 32 KB
Operating Voltage1.6 V to 5.5 V
Low Power ModesHALT, STOP, SNOOZE
CPU Architecture16-bit
Temperature Range-40°C to +85°C
PackageLQFP
Timers16-bit timers
Communication InterfacesUART, I2C, LIN
A/D Converter12-bit

Related product manuals