RESULT INTERPRETATION/REPORTS, Select Display, Read FD
Sysmex SF-3000 Operator's Manual -- Revised September 1995 4-37
(3) The data read from the disk will be displayed in a list. This data can be processed
in the same way as stored sample data.
Search
Select
Display
Edit
Info.
SortGraphic Valid.
More Return
Sysmex
DP:1234567890123
XM HC GP DP SU
Ready
Manual Mode Next No.1234567890123
Sampler
Next
Prev
Mark
Stored Data 0 / 50 (500)=From FD =
DATE TIME SEQ. SAMPLE NO. RACK TUBE OUT POS ERROR MARK STOP
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
10:58
11:00
11:00
11:01
11:01
11:02
11:02
11:03
11:03
11:04
11:04
11:05
11:05
11:06
11:06
11:07
11:07
11:08
11:08
11:09
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
123-56789-101*I
123-56789-101*I
123-56789-102 I
123-56789-103 I
ERR0000000001
ERR0000000002
123-56789-106 I
123-56789-107 I
123-56789-108 I
123-56789-109 I
123-56789-110 I
123-56789-111 I
123-56789-112 I
123-56789-113 I
123-56789-114 I
123-56789-115 I
ERR0000000003
ERR0000000004
ERR0000000005
ERR0000000006
1011
1011
1011
1011
1011
1011
1011
1011
1011
1011
1012
1012
1012
1012
1012
1012
1012
1012
1012
1012
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DMC
D
DMC
DMC
M
DMC
D
C
DMC
DMC
DMC
DMC
Func.
Func.
Func.
Result
Func.
Func.
Func.
Func.
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Figure 4-24: FD Data List Screen
If data cannot be read, the message "FD read Error. Insert FD and press OK key"
will appear in a window. Insert the correct disk and press [OK]. To cancel the
process and exit the program, press [Cancel].
DATE TIME SEQ. SAMPLE NO. RACK TUBE OUT POS ERROR MARK STOP
Sysmex
DP:1234567890123 XM HC GP DP SU
Ready Manual Mode Next No.1234567890123
Sampler
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
10:58
11:00
11:00
11:01
11:01
11:02
11:02
11:03
11:03
11:04
11:04
11:05
11:05
11:06
11:06
11:07
11:07
11:08
11:08
11:09
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
123-56789-101*I
123-56789-101*I
123-56789-102 I
123-56789-103 I
ERR0000000001
ERR0000000002
123-56789-106 I
123-56789-107 I
123-56789-108 I
123-56789-109 I
123-56789-110 I
123-56789-111 I
123-56789-112 I
123-56789-113 I
123-56789-114 I
123-56789-115 I
ERR0000000003
ERR0000000004
ERR0000000005
ERR0000000006
1011
1011
1011
1011
1011
1011
1011
1011
1011
1011
1012
1012
1012
1012
1012
1012
1012
1012
1012
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DMC
D
DMC
DMC
M
DMC
D
C
DMC
DMC
DMC
DMC
Func.
Func.
Func.
Result
Func.
Func.
Func.
Func.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Insert FD and press OK key.
Search Return
Select
Display
Output
Sort
Graphic
Valid.
More
Next
Mark
Prev
Cancel O K
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
FD read Error
= ALL SAMPLES=Stored Data
0 / 500 (500)
Figure 4-25: FD Read Error Message Window
NOTE: Do not remove the floppy disk before you have exited the FD Read
program. If the floppy disk was removed before exiting FD Read
program, the list will be automatically changed to List Display of All
Samples.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYSMEX SF-3000 and is the answer not in the manual?

SYSMEX SF-3000 Specifications

General IconGeneral
BrandSYSMEX
ModelSF-3000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals