Page #161 background image
RESULT INTERPRETATION/REPORTS, Output Stored Data
Sysmex SF-3000 Operator's Manual -- Revised September 1995 4-53
11.4 Cancel Output
Use this program to cancel data output process after it has begun.
To execute cancellation:
(1) Press the [Stored Data] keypad in the Root Menu. The List Display with second
menu keys will appear.
(2) Press the [Output] keypad in the second menus. The Select Sample window will
appear.
DMC
D
DMC
DMC
M
DMC
D
C
DMC
DMC
DMC
DMC
Sysmex
DP:1234567890123
XM HC GP DP SU
Ready Manual Mode Next No.1234567890123
Sampler
Stored Data
900/1000(1000)
= ALL SANPLES =
DATE TIME SEQ. SAMPLE NO. RACK TUBE OUT POS ERROR MARK STOP
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
10:58
11:00
11:00
11:01
11:01
11:02
11:02
11:03
11:03
11:04
11:04
11:05
11:05
11:06
11:06
11:07
11:07
11:08
11:08
11:09
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
123-56789-101*I
123-56789-101*I
123-56789-102 I
123-56789-103 I
ERR0000000001
ERR0000000002
123-56789-106 I
123-56789-107 I
123-56789-108 I
123-56789-109 I
123-56789-110 I
123-56789-111 I
123-56789-112 I
123-56789-113 I
123-56789-114 I
123-56789-115 I
ERR0000000003
ERR0000000004
ERR0000000005
ERR0000000006
1011
1011
1011
1011
1011
1011
1011
1011
1011
1011
1012
1012
1012
1012
1012
1012
1012
1012
1012
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
Func.
Func.
Func.
Result
Func.
Func.
Func.
Func.
C
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Search
Select
Display
OutputSortGraphic
Valid.
More Return
Next
Mark
Prev
Select Sample
Cancel
Output
All
Marked
Current
Cancel
Figure 4-39: Select Sample Window
(3) Press [Cancel Output] key. The Select Device window will appear.
(4) Select a device by pressing [DP], [GP Graph], [GP List] or [HC] keypad. The
output to the selected device will be canceled.
Press [Cancel] to quit the cancellation and to return to the List Display. The output
being executed is continued.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYSMEX SF-3000 and is the answer not in the manual?

SYSMEX SF-3000 Specifications

General IconGeneral
BrandSYSMEX
ModelSF-3000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals