EasyManuals Logo

SYSMEX SF-3000 User Manual

SYSMEX SF-3000
605 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #164 background imageLoading...
Page #164 background image
RESULT INTERPRETATION/REPORTS, Output Stored Data, FD (Backup)
4-56 Sysmex SF-3000 Operator's Manual -- Revised September 1995
(5) To cancel processing and to exit the program, press [Cancel].
To start the backup, insert the disk into the drive and press [OK]. The specified
data will be written onto the floppy disk. While writing is in progress, the message
"Writing..." will appear (see Figure 4-43).
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
DATE TIME SEQ. SAMPLE NO. RACK TUBE OUT POS ERROR MARK STOP
Sysmex
DP:1234567890123 XM HC GP DP SU
Ready
Manual Mode Next No.1234567890123
Sampler
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
10:58
11:00
11:00
11:01
11:01
11:02
11:02
11:03
11:03
11:04
11:04
11:05
11:05
11:06
11:06
11:07
11:07
11:08
11:08
11:09
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
123-56789-101*I
123-56789-101*I
123-56789-102 I
123-56789-103 I
ERR0000000001
ERR0000000002
123-56789-106 I
123-56789-107 I
123-56789-108 I
123-56789-109 I
123-56789-110 I
123-56789-111 I
123-56789-112 I
123-56789-113 I
123-56789-114 I
123-56789-115 I
ERR0000000003
ERR0000000004
ERR0000000005
ERR0000000006
1011
1011
1011
1011
1011
1011
1011
1011
1011
1011
1012
1012
1012
1012
1012
1012
1012
1012
1012
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DMC
D
DMC
DMC
M
DMC
D
C
DMC
DMC
DMC
DMC
Func.
Func.
Func.
Result
Func.
Func.
Func.
Func.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Writing...
Stop
Search Return
Select
Display
Output
SortGraphic
Valid.
More
Next
Mark
Prev
= ALL SAMPLES =Stored Data
900/1000 (1000)
1 / 3
Figure 4-43: FD Writing Message Window
(6) Press [Stop] to stop writing and exit the program.
(7) If the specified data cannot be written onto the floppy disk, the message "FD write
Error! Insert FD and press OK key" will appear in the FD write window.
NOTE: When the floppy disk becomes full, this same error message is
displayed. Insert a new pre-formatted floppy disk.
XM HC GP DP SU
Ready
DP:1234567890123
Stored Data = ALL SAMPLES = 900/1000(1000)
DATE TIME SEQ. SAMPLE NO. RACK TUBE OUT POS ERROR MARK STOP
Sysmex
Manual Mode Next No.1234567890123
Sampler
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
12/04
10:58
11:00
11:00
11:01
11:01
11:02
11:02
11:03
11:03
11:04
11:04
11:05
11:05
11:06
11:06
11:07
11:07
11:08
11:08
11:09
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
123-56789-101*I
123-56789-101*I
123-56789-102 I
123-56789-103 I
ERR0000000001
ERR0000000002
123-56789-106 I
123-56789-107 I
123-56789-108 I
123-56789-109 I
123-56789-110 I
123-56789-111 I
123-56789-112 I
123-56789-113 I
123-56789-114 I
123-56789-115 I
ERR0000000003
ERR0000000004
ERR0000000005
ERR0000000006
1011
1011
1011
1011
1011
1011
1011
1011
1011
1011
1012
1012
1012
1012
1012
1012
1012
1012
1012
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
A 10
A 1
A 2
A 3
A 4
A 5
A 6
A 7
A 8
A 9
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DGH
DMC
D
DMC
DMC
M
DMC
D
C
DMC
DMC
DMC
DMC
Func.
Func.
Func.
Result
Func.
Func.
Func.
Func.
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
FD write Error!
Cancel
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Insert FD and press OK key.
O K
Search
Return
Select
Display
Output
Sort
Graphic
Valid.
More
Next
Mark
Prev
Figure 4-44: FD Write Error Message Window

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYSMEX SF-3000 and is the answer not in the manual?

SYSMEX SF-3000 Specifications

General IconGeneral
BrandSYSMEX
ModelSF-3000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals