1030 HEIDENHAIN Technical Manual MANUALplus 620
The configuration object CfgFeedLimits of the respective parameter set 
defines the minimum and maximum spindle shaft speed for each gear range. 
The list must be sorted in ascending order, with the smallest shaft speed at 
the top. Gear ranges are not supported if the list is missing or empty. 
Module 9163 reports an error if it is called from a PLC program using the 
numerical TNC API version 1.0.
MP_gearSpeed0
Key names of parameter sets for gear ranges (operating mode 
0)
Available from NCK software version: 597 110-02.
Format: Array [0...99]
Input: List with key names for spindle parameter sets for operating 
mode 0.
Default: –
Access: LEVEL3
Reaction: RESET
MP_gearSpeed1
Key names of parameter sets for gear ranges (operating mode 
1)
Available from NCK software version: 597 110-02.
Format: Array 
Input: List with key names for spindle parameter sets for operating 
mode 1.
Default: –
Access: LEVEL3
Reaction: RESET