January 2012 6.20 Commissioning 1073
In the list of motors, the memory location (OEM or HEIDENHAIN motor table),
the type of motor (synchronous, asynchronous, or linear motor), the operating
mode (wye/delta) and the maximum current are displayed in addition to the
motor designation.
Once you have selected the motor and power module, and have confirmed
this with the ENT key or the OK soft key, the selected models are
automatically entered in MP_motName and MP_ampName for the
respectively open parameter set.
If you use motors or power modules that are not listed in the menus, please
contact HEIDENHAIN.
You can overwrite standard data or add other models to the OEM motor table.
The OEM motor table is stored in the PLC partition:
PLC:\table\MOTOR_OEM.MOT
To open the OEM motor table, press the OEM soft key in the table editor. In
the list view, the MANUALplus 620 marks all motors from the OEM table with
an "*" in the OEM column.
Meaning of the soft keys
Scroll back one page in the list
Scroll forward one page in the list
Confirm selection
Cancellation, do not confirm value
Open OEM motor table in the table editor
Open HEIDENHAIN motor table in the table editor
(write-protected)
Open power module table (inverter.inv) in the table editor
(write-protected)
Open power supply module table (supply.spy) in the table
editor (write-protected)
Copy selected value to clipboard
Paste value from clipboard