1074 HEIDENHAIN Technical Manual MANUALplus 620
The data in the HEIDENHAIN motor table and in the inverter.inv power 
module table on the SYS partition is write-protected. You can open the tables, 
but you cannot edit them.
If you use a motor that appears in the motor table, but only the data for the 
speed encoders differs, you can overwrite this data in the motor table with 
MP_motStr, MP_motDir and MP_motEncType. The motor table is not 
actually changed. The changes only take place in the working memory. 
MP_name
Type of power supply module
Available from NCK software version: 597 110-05.
Format: Selection menu
Selection: Name of the power supply module from the "supply.spy" power 
supply module table (entered automatically by the 
MANUALplus 620)
Default: –
Access: LEVEL3
Reaction: RESET
MP_motSupply
Key name of the motor's power supply module
Available from NCK software version: 597 110-05.
Format: Selection menu
Selection: Enter the key name of the power supply module that drives this 
motor. All power-supply-module key names defined under 
CfgSupplyModule are available for selection.
Default: –
Access: LEVEL3
Reaction: RUN
MP_ampName
Type of axis/spindle power module
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Name of the power module from the inverter.inv power module 
table (entered by the MANUALplus 620)
Default: –
Access: LEVEL3
Reaction: RESET
The power module table of older HEIDENHAIN contouring controls, 
MOTOR.AMP, is no longer supported by the MANUALplus 620!
The original entry from the motor table is only used if MP_motStr, 
MP_motDir and MP_motEncType are not in the configuration.