January 2012 6.20 Commissioning 1075
MP_ampAdditionalInfo
Configure the switch position of the current sensor (column "S" 
of the inverter.inv power module table). Is required for the D 
series of HEIDENHAIN inverters (UM 1xx D) in order to use the 
higher currents at the lower PWM frequencies. 
Available from NCK software version: 597 110-04.
Format: Numerical value (32 bits)
Input: Bit 0 – Configure the switch position of the current sensor in 
HEIDENHAIN inverters of the "D" series (UM 1xx D).  
Bit 0 = 0: "S" in inverter.inv table = 0
Bit 0 = 1: "S" in inverter.inv table = 1
Bit 1- Reserved
Bit 2- Reserved
Bit 3 – Inverter manufacturer
Bit 3 = 0: Non-HEIDENHAIN inverter
Bit 3 = 1: HEIDENHAIN inverter
Default: -
Access: LEVEL3
Reaction: RUN
MP_motName
Motor model
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: Name of the selected motor from the motor table (entered by 
the MANUALplus 620)
Default: –
Access: LEVEL3
Reaction: RESET
MP_motDir
Overwrite the "counting direction" of the motor encoder from 
the motor table
Available from NCK software version: 597 110-03.
Format: Selection menu
Selection: Off
Value from the motor table active
Positive
Positive counting direction
Negative
Negative counting direction
Default: No value, parameter optional (value from motor table in effect)
Access: LEVEL3
Reaction: RESET