January 2012 6.20 Commissioning 1077
Entries in the power
supply module
table:
(supply.spy)
NAME: Designation of the power supply module
E-R: Type of power supply module
0: No regenerative module
1: Regenerative module
P-N: Rated power in W
P-S6-40: Peak power (S6-40) in W
P-MAX02: Peak power for (0.2 s) in W
UZ: DC-link voltage in V
UZ-AN: Ratio of measuring voltage / UZ in V/V
IZ-AN: Ratio of measuring voltage / IZ in V/A
STATUS-SIG: Status signals
Bit#0: AC-FAIL
Bit#1: POWERFAIL
Bit#2: TEMP
Bit#3: READY
Bit#4: Reserved
Bit#5: Reserved
Bit#6: Reserved
Bit#7: Reserved
T1:
P-D: Proportional factor of D controller
I-D: Integral factor of D controller
P-Q: Proportional factor of Q controller
I-Q: Integral factor of Q controller
FREQ: PWM frequency in HZ