1184 HEIDENHAIN Technical Manual MANUALplus 620
Counters for axis
commands
(Diag Counter)
To select the Diag Counter function:
Press the Login Ipo (or Login SimIpo) soft key.
Press the Axes soft key.
Press the Diag Counter soft key.
All counters are reset to 0 when the control is started. The function displays
the following counters:
Variable Display
cntrActToNom Number of nominal/actual position captures
cntrFeedHold Number of changes of the feed-rate enable
cntrM3 Number of M3 commands
cntrM4 Number of M4 commands
cntrM5 Number of M5 commands
cntrHwheel Number of handwheel commands