1200 HEIDENHAIN Technical Manual MANUALplus 620
Command to the CC
(CC Command)
This function transfers commands directly to the CC.
To select the CC Command function:
Press the Login Ipo soft key.
Press the HW soft key.
Press the CC Command soft key for the OLM to open the "CC
Command" dialog box.
Enter the required data in the dialog box (see below).
Enter the required data in the dialog box (see below).
Confirm with OK—the OLM sends the defined command to
the CC.
CC_Command dialog box:
Dialog box entries:
Function: Command sent to the CC
AxMpUebern
•MotTemp
DriveOnReq
AntriebAus
Status
CHK_PHIFELDREF
SHOW_HW_CO...
Info: Not used
Axis no: Logical axis number
Danger
Please note that commands transferred to the CC with this function are not
checked by the system.
Do not use these functions to switch drives on or off, since the brakes will
not be activated or deactivated.