January 2012 6.22 Diagnosis with the Online Monitor (OLM) 1201
Data of the static
RAM (S-RAM)
This function displays the data stored in the static RAM of the IPO.
To select the S-RAM function:
Press the Login Ipo (or Login SimIpo) soft key.
Press the HW soft key.
Press the S-RAM soft key.
The function displays the following variables:
Data of the analog
outputs (Analog
Output)
Use AnalogOutput to display the nominal commands. – The values of the
outputs are not returned.
To select the Analog Output function:
Press the Login Ipo (or Login SimIpo) soft key.
Press the HW soft key.
Press the Analog Output soft key.
The function displays the values of the analog outputs in [V]:
Output1
Output2
...
Output16
Variable Display
kennung1 Internal code
kennung2 Internal code
absActPos Switch-off position of the individual axes
absActPosNonMod Switch-off position of the individual axes
refPosition Reference position of the individual axes
modCntrEndat Overflow of multiturn EnDat encoder
checkSum Checksum of current machine parameters
valid Validity code