January 2012 6.22 Diagnosis with the Online Monitor (OLM) 1211
The OLM uses the selected data to generate a bit line. The bit line is displayed
in the bottom screen line at right. You can also use the bit line in the start batch
of the IPO to start the IPO with the Debug Print function.
Meaning of the data:
Variable Display
parameter Output of information during parameter assignment. In
addition, the parameters for every axis that are sent to
the CC are written to the file r:\runtime\_HelpTrace.txt.
referencing Output of information during reference run
monitoring Output of information during standstill monitoring and
during monitoring of the absolute position (from zero
pulse to zero pulse for distance-coded encoders)
axisCommands Output of internal axis commands
axisValues Output of information during actual-value transfer
measuring Output of information on measuring process (probe on/
off, monitoring, etc.)
tracePlcIpoMsg All messages that are sent to the PLC-IPO are written
to r:\runtime\_HelpTrace.txt.
initIpoChain Output during the initialization of the IPO chain
traceIpoMsg All messages that are sent to the IpoInterpolator are
written to r:\runtime\_HelpTrace.txt.
handwheel Output of information during the configuration and
selection of the handwheel
ipoFilter Output of information during the configuration and
selection of two filters in the IPO chain
singleStep Output of information during graphic simulation in the
SingleStep mode of operation
sg Output of additional information from the safety-
oriented package (SG: safety-oriented control)
sgIo Output of additional information from the safety-
oriented package
sgPos Output of additional information from the safety-
oriented package
sgCyclic Output of additional information from the safety-
oriented package
spindleCmds All spindle commands and their acknowledgments are
recorded.
EmStopTest Outputs during the emergency stop test
IpoIpoAchse Output during the configuration of the axes of a channel
(exchanging axes in and removing axes from the
interpolation context)