1234 HEIDENHAIN Technical Manual MANUALplus 620
MP_simMode
Specify the type of programming station mode
Available from NCK software version: 597 110-02.
Format: Selection menu
Selection: FullOperation
Programming station mode is switched off, the emergency-
stop loop (X41/34 and X42/4) must be complete. The drives are
moved.
CcOnly
Simulation of the CC controller unit. All PLC inputs and outputs,
as well as the emergency-stop circuit, must be connected
correctly in order to switch the control on correctly.
CcAndExt
Simulation of the CC controller unit and all PLC inputs and
outputs. The emergency-stop loop does not need to be
complete. The PLC runs in simulation mode.
Delivery
Mode for commissioning.
During power-up, all axes are automatically put into the test
mode. The drives cannot be switched on. In this way, the
control can be started even with an incomplete or faulty axis
configuration.
Default: FullOperation
Access: LEVEL3
Reaction: RESET
Traversing the reference position of the axes can be skipped in programming
station mode.
Set the MP_skipReferencing parameter to the value TRUE in order to set the
axes directly on the reference position when the control is started.
MP_skipReferencing
Fast reference run
Available from NCK software version: 597 110-02.
Format: Selection menu
Selection: FALSE
The axes are not set on the reference position.
TRUE
The axes are set directly on the reference position when the
control is started.
Default: FALSE
Access: LEVEL3
Reaction: RESET