January 2012 7.9 Operating Times and System Times 1377
Module 9192 Transfer the operating hours counter
The module reads the given PLC or NC operating hours counter.
The current value is transferred in seconds. If the value is greater than
2 147 483 648 (approx. 69 years), a negative number will be transferred.
Call:
PS B/W/D/K <Number of the operating time>
–3: Control on
–2: Machine on
–1: Program run
0 to 7: PLC operating time counter 1 to 8
CM 9192
PL B/W/D <Current time [s]>
–1: Error
Error recognition:
Module 9193 Set the operating hours counter
The module overwrites the given PLC or NC operating hours counter. The old
value is lost irretrievably.
The value of the NC operating hours counters may only be changed in
exceptional cases (e.g. when the control is exchanged).
The time for Control on cannot be overwritten.
Transfer all values greater than 2 147 483 648 (approx. 69 years) as negative
numbers.
Call:
PS B/W/D/K <Number of the operating time>
–3: Control on
–2: Machine on
–1: Program run
0 to 7: PLC operating times 1 to 8
PS B/W/D/K <New time [s]>
CM 9193
Error recognition:
Marker Value Meaning
NN_GenApiModule
Error
0 PLC operating time was read
1 Incorrect transfer value, or module was not
called in a spawn or submit job
Marker Value Meaning
NN_GenApiModule
Error
0 Operating time was overwritten
1 Incorrect transfer value, or module was not
called in a spawn or submit job