1450 HEIDENHAIN Technical Manual MANUALplus 620
Dashboard display
of the parallel axes
(U, V, W)
To be able to display the positions of the parallel axes in the dashboard, copy
the dashboard element DB_C1 located in CfgDashboardElemnt and
rename it to DB_U1, DB_V1 or DB_W1.
Then enter the dashboard elements (DB_U1, DB_V1, DB_W1) into the
elementList of a dashboard display (e.g. DB_DEFAULT).
Settings in the configuration editor MP number
DisplaySettings
CfgDashboardElemnt
DB_U1
dashboardpicType: ActualCAxisValue
attribut: 0
entityList: U1
DB_V1
dashboardpicType: ActualCAxisValue
attribut: 0
entityList: V1
DB_W1
dashboardpicType: ActualCAxisValue
attribut: 0
entityList: W1
113100
113101
113102
113103
...
Settings in the configuration editor MP number
DisplaySettings
CfgDashboard
DB_DEFAULT
elementList
113200
113201