January 2012 8.5 Data Organization 1543
MP_mainPgm
Path and file name of the PLC main program
Format: String 
Input: Max. 260 characters
Path and file name of the PLC main program
Example: %OEM%\PLC\main.src
Default: –
Access: LEVEL3
Reaction: NOTHING
MP_pwmPgm
Path and file name of the PLC commissioning program
Format: String 
Input: File name and path of the PLC program for commissioning the 
current controller. This PLC program is compiled and used as an 
alternative if the machine parameter 
MP_currentControlAdjust (System/CfgHardware) is set to 
"on."
Example: %OEM%\PLC\SetUp.plc 
Default: –
Access: LEVEL3
Reaction: NOTHING
MP_errorTable
Path and file name of the PET table
Format: String 
Input: Max. 260 characters
Path and file name of the PLC error table
Example: %OEM%\PLC\LANGUAGE\ERR_TAB.PET
Default: –
Access: LEVEL3
Reaction: NOTHING
MP_errorText
Name of the text file for PLC error texts
Format: String 
Input: Max. 260 characters
Name (without path) of the text file for PLC error texts.
The language-sensitive text files must be saved in 
language-specific directories that cannot be changed.
Example: ErrorText.csv
Default: –
Access: LEVEL3
Reaction: NOTHING