1544 HEIDENHAIN Technical Manual MANUALplus 620
MP_dialog
Name of the text file for PLC dialogs
Format: String 
Input: Max. 260 characters
Name (without path) of the text file for PLC error texts.
The language-sensitive text files must be saved in 
language-specific directories that cannot be changed.
Example: dialog.csv
Default: –
Access: LEVEL3
Reaction: NOTHING
MP_softkeyProject
Path and name of the project file for PLC soft keys
Format: String 
Input: Max. 260 characters
Path and name of the file
Example: %OEM%\BasisPgm\Softkeys\softkeys.xrs
Default: –
Access: LEVEL3
Reaction: NOTHING
MP_compErrorTable
Path and file name of the error table of the PLC compiler
(Value preset by HEIDENHAIN and should not be changed!)
Format: String 
Input: Max. 260 characters
Path and name of the file
Default: %SYS%\config\plccomp.ert
Access: LEVEL3
Reaction: NOTHING
Be sure not to change the default value in MP_compErrorTable, or proper 
operation of the PLC compiler can no longer be guaranteed.