January 2012 8.8 T Functions (T Strobe) 1579
MP_externalTool
Symbolic name or number of the PLC marker that is set during
decoding if a tool is loaded that is not in the magazine
Available from NCK software version: 597 110-03.
Format: String
Input: Max. 80 characters
The definition of this marker is not necessary if the magazine
and pocket numbers are evaluated elsewhere or are irrelevant.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
MP_internalTool
Symbolic name or number of the PLC marker that is set during
decoding if a tool is loaded that is in the magazine
Available from NCK software version: 597 110-03.
Format: String
Input: Max. 80 characters
The definition of this marker is not necessary if the magazine
and pocket numbers are evaluated elsewhere or are irrelevant.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
MP_specialTool
Symbolic name or number of the PLC marker that is set during
decoding if a special tool is loaded
Available from NCK software version: 597 110-03.
Format: String
Input: Max. 80 characters
Default: The definition of this marker is not necessary if no special tools
are used.
Access: LEVEL3
Reaction: RESET