368 HEIDENHAIN Technical Manual MANUALplus 620
Machine
parameters
Machine parameters in the CfgOemPassword configuration object:
MP_funcList
List of function names (= key names) that are called by entering
the password:
Available from NCK software version: 597 110-01.
Format: Array 0...200
Input: Key name of max. 18 characters
Name of the functions that are called by entering the password.
Enter these names as key names in CfgModOemSoftkey and
CfgCfgEditActivate.
The key name of CfgOemPassword defines the password.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
Machine parameters in the CfgModOemSoftkey config object:
MP_activation
Specifies whether the defined function is a foreground
application.
Available from NCK software version: 597 110-01.
Format: Selection menu
Selection: TRUE
The defined function is a foreground application, e.g.
configuration editor. Set this value if the soft key opens the
configuration editor to display user parameters.
FALSE
Function performed in the background
Default: FALSE
Access: LEVEL3
Reaction: RESET
MP_skPos
Position of the soft key in the 3rd menu bar
Available from NCK software version: 597 110-01.
Format: Numerical value
Input: 0 to 7
0: first soft key from the left
No input: the soft key is not displayed
Menu bars 1 and 2 are reserved for HEIDENHAIN.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
The buttonText folder contains two machine parameters used to define the
labeling of the soft key. You can either define a reference to the text in a
language-sensitive *.CSV file or a language-neutral text. Leave the
buttonText empty if you want to define an image for the soft key with
MP_buttonImage.