January 2012 4.3 User Parameters 369
MP_dialogRes
Reference to a language-sensitive text in a *.CSV file.
Available from NCK software version: 597 110-01.
Format: String 
Input: Max. 40 characters
Example:
OEMTXT_001_ncLanguage
The designator must be available in a text resource file (*.CSV). 
The text file must be defined under
System/Paths/CfgOemPath/dialogTextfile.
Leave the parameter empty if you do not want the soft key 
labeling to be language-sensitive. Enter the text directly under 
MP_text instead.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
MP_text
Soft key designator.
Available from NCK software version: 597 110-01.
Format: String 
Input: Max. 60 characters
Enter a language-neutral text. If a language-sensitive text was 
defined with MP_dialogRes you must not change the displayed 
string; the control displays the entry from a *.CSV file.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
MP_buttonImage
Image for soft keys
Available from NCK software version: 597 110-01.
Format: String 
Input: Path/file name to an image for a soft key
Leave the parameter empty if you have defined a text for the 
soft key under buttonText.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET
MP_funcKey
Key name of the function being activated when the soft key is 
pressed
Available from NCK software version: 597 110-01.
Format: String 
Input: Max. 18 characters
The key name must be entered only if the name of the function 
does not match the key name.
Default: No value, parameter optional
Access: LEVEL3
Reaction: RESET