412 HEIDENHAIN Technical Manual MANUALplus 620
watchdogTime
100303
MP2172
Delayed switch-off of SH1
Define the recovery time for watchdog 2 here.
Format: Numerical value
Input: 1 to 30 [s]
Default: 3 [s]
RUN
LEVEL3
989
CfgFilter
Default configuration of position command filters, applies to all axes.
Can be overwritten axis-specifically.
defaultPosition:
Default configuration of the position command filter for all linear axes
shape
100405
Shape of the nominal position value filter
Format: Selection menu
Input:
Off:
Filter is off
Average:
Mean-value filter
Triangle:
Single filter
HSC:
HSC filter (High Speed Cutting)
(setting for "accuracy" criterion)
Advanced HSC:
Advanced HSC filter (High Speed Cutting)
(setting for "surface" criterion)
Allowed in
strobe
LEVEL3
597 110-05
814
frequency
100405
Cutoff frequency of the nominal position value
filter
Format: Numerical value
Input: 0 to 1000 [Hz]
Max. 9 decimal places
Default: 20 [Hz]
Allowed in
strobe
LEVEL3
597 110-05
814
Parameter
MP number
iTNC MP number
Function and input Behavior
Access
SW vers.
Page